- Dual Oxygen Controllers -- Each controller has it's own independent and intelligent power supply. APD
CCR's are the only rebreathers with two independent controllers each capable of controlling the oxygen
solenoid. The controllers are responsible for maintaining the chosen PO2 set-point by firing the oxygen
injection solenoid using voting logic with the three oxygen sensors.
- Heads Up Display - Two indications for each controller: two pairs of LED's, green on the bottom, red on
the top. Solid green indicates all is well, flashing LED's or solid red indicate various types of alerts or
events. The brightness of the LED's can be changed at any time.
- Audible Alarm - A buzzer provides a distinct sound to to alert the diver to review an important change in
status being displayed on the handset. Non-critical alarms can be temporarily supressed by the diver.
- CO2 Scrubber Life Monitor - shows you real-time that CO2 absorption is occurring in the scrubber. The
Scrubber Life Monitor performs reliably and consistently regardless of depth or water temperature, during
ascents and descents, giving warnings at appropriate times on the HUDs and buzzer.
- Full Nitrox/Trimix Support - The dive computer supports any breathing mixture of Nitrogen, Oxygen, and
optionally Helium. As many as six different gas mixes can be defined by the diver and selected as diluent or open
circuit gases at any time during a dive.
- Decompression information - Based on the real-time PO2 in the breathing circuit and real-time depth,
using the Bühlmann ZHL16A-1b algorithm with user programmable gradient factor values. The display shows
No Stop Time, which reverts to Total Time to Surface (TTS) and ceiling depth once the diver requires
decompression stops.
- Real-time Data Log - PC downloadable information includes up to 9 hours of the most recent data recorded
in 10 second intervals. Data recorded includes depth/time dive profile, PO2 from all 3 cells, set points,
scrubber probe temperatures, any cell errors or warnings and surface interval, decompression, ambient
temperature, battery voltages, and oxygen exposures (CNS, OTUs).
- Imperial or Metric Units of Measure - The computer can be set to display depths in either feet or meters
of sea water.
to download the Vision Simulator software (1.4MB)
to read The Unmatched Power of the Vision Electronics
Regulators, SPGs and Hoses
The Inspiration/Evolution rebreathers use APD's own first stage regulators designed and tuned for their
rebreathers. The Oxygen regulator has an over pressure valve installed in a low pressure port, the diluent
regulator relies on the Auto-Air second stage for over pressure relief. Each regulator has a 1.5-inch
submersible pressure gauge reading in PSI (optionally available in BAR) and the Oxygen SPG has a color coded
green boot. The oxygen regulator supplies a manual addition valve and the oxygen injection solenoid. The
diluent regulator supplies multi-port manifold block to simplify hose routing. The diluent manifold block
supplies a manual addition valve, ADV, and the Auto-Air BC integrated second stage. Most of the hose fittings
are screw-on type. The screw-on fittings are proven more reliable than common crimped on fittings and they make
for very easy customizing and repairs. Simply unscrew the hose ends, cut the hose shorter or replace it and
screw the fittings back on again. You can do this with two ordinary adjustable wrenches, even in the remotest
parts of the world.
Harness and Wing
The APD harness and Wing are specifically tailored to provide an ideal mate with your rebreather and are
included in the price. The APD rebreather harness is available in your choice of four sizes, along with
the 35 lb wing. The harness holds the rebreather securely on you, includes fastenings to keep hose routing
tidy, an integrated weight system holding up to 12 lbs per side, and has plenty of D-Rings for attaching side
tanks and accessories. The Inspiration model can also accept a larger 50 lb wing. Both sizes have weight trim
pockets high up to ensure a perfect swimming position and D-rings at the sides which when used with the
optional Verti-clips allow easy one handed attachment of side slung tanks.

Cylinders
Our price includes the gas supply cylinders and valves. The tanks are Faber FX series steel
15 cubic foot cylinders (2L water volume)
with a 3442 psi service pressure and have both U.S. DOT and Canadian TC markings. The neck threads are the US
standard 3/4-NPS, but they require an included APD valve which has the hand wheel and supply opening inline
with each other. The Evolution cylinders are more than adequate to support over three hours of
sport diving, but we recommend carrying an external bailout.
Physical Characteristics
The hi-impact ABS plastic case body and hard-shell cover holds all the
components securely in place and is streamlined to fit body contours with maxium protection.
The durable cover is bright yellow color (optional black available)
to improve visibility in low light or silty conditions. Quick-release fasteners allow for easy access to
both the scrubber canister and gas supply cylinders. Our standard package includes the sturdy and low weight
carry case.
| Evolution |
| Fully Configured Weight |
54 pounds |
| CCR Dimensions (LxWxD) |
19x16x14 inches |
| Carry Case (LxWxD) |
30x18x15 inches |
Starter Pack
Included in our package with every rebreather is a Starter Pack. The Starter Pack includes a
hardcopy CCR manual, AutoAir Manual, BC Manual, Software CD, Bridge PC Link interface and cables. The pack
includes three sizes of HUD clips, IP Gauge, two batteries, crotch strap, oxygen sensor connector, and
alternative handset strap. We also include a 'bubble chaser' o-ring kit with a dozen of the most commonly
needed o-rings, a spare scrim, free disinfectant samples and a spray bottle. There's a nice small dry box and
logo hat too!
Consumables
The recommended consumables are: Energizer CR-P2 6.0V lithium battery, Molecular Products Sofnolime 8-12 mesh
(1-2.5 mm granules) CO2 absorbent, DuPont RelyOn MDC (formerly Virkon) 1% solution for breathing loop
disinfection, Aerospace Lubricants Tribolube 71 oxygen compatible lubricant for O-ring seals, and
Caig Labs DeoxIT GOLD for cleaning gold electrical contacts.
Training
The rebreathers requires formal training for safe use. The pricing does not include
training, and training is solely the responsibility of the purchaser. Training is available worldwide from
APD approved instructors. The training time is
five to seven days consisting of a classroom lecture, confined water session and at least seven OW dives. Fill
Express also offers instruction at our International Training Center in SE Florida.
When you purchase your rebreather, we suggest you immediately complete the required
Liability Release and fax it to Silent
Diving Systems at 603-297-0047. When you begin training, because the liability release is already on file, your
instructor will only need contact SDS and provide the serial number of your unit. SDS will register the serial
number of the unit in your name and issue, only to your instructor, the software required to enable the
electronics.
|